Pillard LoNOxFlam G3

Printable Version

Product Burners LoNOxFlam G3 -FIVES

Gas burners for industrial fire tubes boilers

Markets/applications

  • Urban heating plan

50 to 75 % Nox reduction

The primary Nox reduction ( Via the sole burners) is very important. Consequently, no need to use a secondary device to reach the specified Nox values, which is a difficult solution to carry out on fire tube boilers.

Process gas firing

In addition to NG & Diesel oil, allows to burn biogas, refinery gas, syngas, process gas up to 80 % H2.

Up to 200°C air

This burner is designed to accept hot combustion air and so, its use is possible for industrial application and is not limited to tertiary field.

Key features

  • 4 to 30 MW per burner
  • Delivered in a package version with individual windbox and air damper

References

Solution patented and described as Best Available Technique in the 2013 BREF edition (BAT Reference Document published by the European Commission).

  • Dalkia
  • SAMSUNG
  • Norske Skog

⇒ For recruitment-related matters (application, etc.), please do not use this form. Make your requests on this page.

In order to address your request, we need to collect the information listed in the form below


*

Despatch of these emails is managed by a FIVES partner located in the United States, an active member of Privacy Shield. The partner guarantees processing compliant with European requirements for personal data protection. Unsubscribe with a single click on a link in the message received.


* required fields

Your message has been sent and will be treated as soon as possible. Thank you for contacting Fives.

Sorry, we encountered a problem, your message was not sent